Energy Efficiency /

Controls Before Capex: Unlocking Savings Through Smarter Building Operations

Why optimizing existing equipment and control sequences should be a priority before investing in new systems

Background Story

When organizations consider energy efficiency improvements, the conversation often begins with replacing old equipment: installing more efficient chillers, upgrading pumps, or replacing air-handling units.

Although equipment replacement can deliver substantial savings, it is not always the first or most cost-effective step.

Many existing buildings already have reasonably efficient equipment but fail to achieve its full potential because of incorrect operating schedules, excessive setpoints, poorly configured control sequences, or equipment running when it is not required.

Building controls determine how equipment operates under real conditions. Even an efficient chiller or variable-speed pump can consume unnecessary energy if it is operated incorrectly.

Optimizing these controls can unlock savings with limited capital investment, while helping building owners identify where equipment replacement is genuinely necessary.




Problems
 

 

  • Incorrect operating schedules: HVAC systems operate before occupancy, after business hours, or during periods of low demand.
  • Excessive setpoints: Chilled-water temperatures, supply-air temperatures, or differential pressure settings may be unnecessarily conservative.
  • Poor equipment sequencing: Multiple chillers, pumps, or cooling towers may operate inefficiently because their staging logic is not optimized.
  • Manual overrides: Temporary adjustments to controls may remain in place long after the original issue has been resolved.
  • Limited integration: Equipment may operate independently rather than responding to actual building demand.
  • Insufficient monitoring: Faulty sensors and control issues may remain undetected, causing persistent energy waste.

These issues can increase electricity consumption, accelerate equipment wear, and compromise comfort without any obvious equipment failure.



Main Objectives
  • Demonstrate the energy-saving potential of control optimization.
  • Explain why operational improvements should be evaluated before major capital expenditure.
  • Highlight the role of Building Management Systems (BMS), sensors, variable-frequency drives, and automated control sequences.
  • Encourage a structured, measurement-based approach to identifying and correcting inefficiencies.
  • Show how operational improvements can complement larger retrofit investments.



Approach

A practical controls optimization program should follow a structured process.
  1. Assess existing operations: Review BMS points, equipment schedules, setpoints, operating sequences, and available energy data.
  2. Identify optimization opportunities: Investigate unnecessary equipment operation, excessive pressure settings, inefficient staging, and operation outside required hours.
  3. Prioritize low-cost ECMs: Consider schedule optimization, demand-based ventilation, chilled-water temperature reset, differential pressure reset, and improved equipment sequencing where technically appropriate.
  4. Implement and test changes: Verify that revised control sequences operate correctly under different loads and weather conditions without compromising comfort, indoor air quality, or equipment safety.
  5. Monitor and sustain performance: Use Energy Management Information Systems (EMIS) or BMS trends to compare performance before and after changes, identify deviations, and prevent unnecessary overrides.



Results

A well-executed controls optimization program can deliver:
  1. Lower energy consumption: Equipment operates only when required and under appropriate operating conditions
  2. Reduced peak demand: Better sequencing and control can help avoid unnecessary simultaneous operation
  3. Lower implementation costs: Some opportunities require software configuration and commissioning rather than major equipment replacement
  4. Improved equipment reliability: Reduced unnecessary runtime and more stable operation may help limit wear
  5. Better occupant comfort: Properly optimized controls can improve temperature stability and system responsiveness
  6. Better investment decisions: Understanding existing system performance helps determine which equipment upgrades are justified and which operational issues should be corrected first
​​​​​​​
The magnitude of savings varies with the building's existing condition, control capabilities, operating hours, and measures implemented. Savings should be established through a suitable baseline and verified after implementation.



Conclusion

Energy efficiency does not always begin with buying new equipment. Sometimes, it begins by making the equipment already installed operate as it should.

​​​​​​​
Before investing in new capacity, make sure you are getting the full performance from the capacity you already have.